I-RPM engcono kakhulu ye-centrifuge yaselabhorethri esetshenziselwa igazi incike ekusetshenzisweni okuqondile (isb., ukuhlukanisa i-plasma, i-serum, noma amaseli egazi). Nazi ezinye izigaba ezijwayelekile ze-RPM zezinhlelo zokusebenza ezahlukene ezihlobene negazi:


1.Ukuhlukaniswa kwePlasma/Serum:

Ngokuhlukaniswa kwe-plasma okujwayelekile noma i-serum, ama-centrifuge ngokuvamile asebenza phakathi kuka-3,000 kuya ku-5,000 RPM. Lokhu kuqinisekisa ukuhlukaniswa okuhlanzekile kwe-plasma/serum kumaseli egazi.


I-Platelet-Rich Plasma (PRP):

Ukuze kukhishwe i-plasma ecebile ngeplatelet, i-centrifuge enesivinini esiphansi ngokuvamile isetshenziswa. I-RPM ivamise ukusuka ku-1,500 kuye ku-3,500 RPM. A eklanywe ngokukhethekile I-PRP centrifuge ilungele ukufeza ukuhlukaniswa okunembile okudingekayo ezinkambisweni ze-plasma-rich rich plasma (PRP). Lawa ma-centrifuge ngokuvamile aklanyelwe ukuthuthukisa ukuhlukaniswa kwamaplatelet ngenkathi kugcinwa ukusebenza kwawo kanye nokugxila kwawo.


3.Ukucubungula Igazi Lonke:

Ngokuhlukaniswa kwegazi lonke, ikakhulukazi ezindaweni zokugcina igazi, ama-centrifuge angase asebenze ngo-2 500 kuya ku-3 500 RPM. Amanye ama-centrifuge akhethekile eza nezilungiselelo zesivinini ezihlelekayo, okuvumela ukulungiswa okunembile okusekelwe ohlotsheni lomkhiqizo wegazi ocutshungulwayo. Ezimweni ezinjalo, a I-Blood Bank Centrifuge kuyisinqumo esihle kakhulu. Lawa ma-centrifuge aklanyelwe ngokukhethekile ukuphatha imikhiqizo ehlukahlukene yegazi, enikeza ukuguquguquka kokulungisa isivinini semisebenzi efana ne-plasma, amangqamuzana egazi abomvu, noma ukuhlukaniswa kweplatelet, okuqinisekisa ukusebenza kahle nokunemba okuphelele.


4.Buffy Coat Isolation:

Lapho uhlukanisa ijazi le-buffy, eliqukethe amaseli amhlophe egazi namaplatelet, i-centrifuge ngokuvamile isebenza cishe ku-1,000 kuya ku-2,000 RPM.


5.Ukuhlukaniswa Kwegazi Okusheshayo:

Ezilungiselelweni ezithile zocwaningo lapho kudingeka khona ukuhlukaniswa okunembe kakhudlwana, ama-centrifuge anesivinini esiphezulu angase asebenze ku-10,000 kuya ku-15,000 RPM. Kodwa-ke, lokhu akuvamile kakhulu ezicelweni zomtholampilo ezijwayelekile.

I-RPM Laboratory Centrifuge


Okucatshangelwayo Okubalulekile:

Isiqandisi: Amasampula egazi ayazwela izinga lokushisa, ngakho-ke a i-centrifuge efrijini ngokuvamile kuyadingeka ukuze kugcinwe ubuqotho besampula, ikakhulukazi phakathi nokuphonswa okude.

Uhlobo Lwe-Rotor: Ukuhlukaniswa kwegazi kuvame ukusebenzisa ama-rotor aphumayo ukuze ahlukanise ngokulinganayo nangempumelelo.

I-RPM Laboratory Centrifuge 2

 

Ngokusetshenziswa kwelabhorethri evamile, i-MKE Lab I-KC-500B noma amamodeli afanayo anebanga lesivinini phakathi kuka-3,000 kuya ku-5,000 RPM kungaba ukukhetha okuthembekile kwemisebenzi yokucubungula igazi. Uma unezidingo ezithile, njenge-PRP noma i-buffy coat isolation, ungase udinge imodeli enezivinini ezilungisekayo ngaphakathi kobubanzi obaluliwe. Siyakwamukela ukuthi usithumelele uphenyo, futhi sizokukhethela imodeli ye-centrifuge engcono kakhulu.