IMikhiqizo EYENZIWE
I-Plasma Gel Card Centrifuge 12/24 I-Id Yokuthayipha Yeqembu Legazi
| Izicelo: | ●Ukuhlolwa kohlobo lwegazi lwe-ABO ●Ukuhlolwa kwe-antigen yeqembu legazi le-Rh ●Ukuhlolwa okungajwayelekile kwe-antibody ●Umdlalo ophambeneyo | ●Ukutholwa kwe-HDN ●Ukuhlolwa kwama-antibody e-platelet ●Umdlalo we-crossmatch we-platelet |
| UMax.Speed | 3500 rpm | |
| I-Max.RCF | 1554xg | |
| Umthamo omkhulu | Amakhadi angama-24 | |
| Ama-Rotors ahambisanayo | Ama-rotor ekhadi lediski | |
| Khombisa | I-LCD | |
| Inombolo Model: | I-XK-12B | |
| Certification: | CE, ISO13485,ISO9001:2015 | |
| Iwaranti | Iwaranti yonyaka ongu-1 yawo wonke umshini, iwaranti yeminyaka emi-3 ye-compressor kanye newaranti yeminyaka emi-5 yemoto. Izingxenye ezishintshayo zamahhala nokuthunyelwa ngaphakathi kwewaranti. | |
- Incazelo
- Ividiyo
- Imininingwane Technical
- Rotors kanye Izesekeli
- Competitive Advantage
Ubuchwepheshe bejeli yekholomu encane busetshenziswa kakhulu ekuhlolweni kwegazi, ekuhlolweni kwe-serum okuvamile, ekuhlanzweni kwamangqamuzana abomvu egazi, ekuhlolweni kwe-immunoassay yejeli ye-microcolumn, nakwezinye izinhlelo zokusebenza ngenxa yokusebenza kwayo okujwayelekile kanye namakhono okuhlola abucayi. I-XK-12B blood gel card desktop centrifuge enejubane eliphansi ene-rotor yamakhadi angu-12/24 ihlangabezana nezidingo zokusebenza ezijwayelekile zokucubungula i-batch. Uhlelo lune-control microcomputer kanye nobuchwepheshe bokuthola ukungalingani okuzenzakalelayo, okuqinisekisa ukusebenza okulula kanye nemiphumela yokuthola enembile. Leli thuluzi libalulekile kwi-hematology yokuhlola ezibhedlela nasemabhange egazi.
Isimiso se-Centrifuge yeKhadi leGeli leGazi (iKhadi le-ID)
Isimiso esingemuva kwe-Blood Gel Card Centrifuge sisekelwe ku-microcolumn gel immunoreaction, ikakhulukazi ukuhlolwa kwe-red blood cell agglutination, okwaziwa nangokuthi i-microcolumn gel hemagglutination assay (MGHA). Ngaphakathi kwe-microcolumn gel tube, amaseli abomvu egazi kanye nama-antibodies awo ahambisanayo ayahlangana ukuze akhe inqwaba yamaseli abomvu egazi. Ngokusebenzisa i-centrifugation esheshayo, i-clot ibekwa ebusweni noma ngaphakathi kwe-gel, kuyilapho amaseli abomvu egazi angaboshelwe ku-antibody ehlala phansi kwe-tube (isihloko se-tube bottom).
Izinzuzo
Izinzuzo ze-Micro Column Gel Technology zifaka phakathi ukulula kokusebenza kwayo, ukuntuleka kokuhlolwa kokuwasha kanye nokuqinisekiswa kwemiphumela emibi, okuxazulula inkinga yokuthi ukuhlolwa kwe-Coombs kunzima ukukusebenzisa njalo emtholampilo ngenxa yobunzima bayo kanye nesimo sayo esithatha isikhathi. Iphinde ikhuthaze inkolelo-mbono yokutholakala kwama-antibody engaphelele ukuthi ibe "izinga legolide" lezokwelapha. Uhlelo lungacubungula amasampula amaningi ngesikhathi esisodwa (amakhadi angu-12/24), okuvumela ukutholakala kwenani elikhulu lamasampula ezokwelapha. Ngaphezu kwalokho, lunikeza izinzuzo ezifana nokunemba, ukuzwela, ukusetshenziswa okuncane kwamasampula, ukugcinwa kwemiphumela isikhathi eside, ukulinganisa okulula, kanye nokusebenza okuphephile.
Indlela Yokuhlola Ubaba
Indlela Yokuhlola Ubaba ihilela ukusetshenziswa kwamakhadi okuhlola uhlobo lwegazi lwe-ABO olune-positive kanye nohlobo olubi kanye nohlobo lwegazi lwe-RhD ukuthola ama-antigen e-ABO kanye ne-RhD yomuntu. Indlela yokuhlanganisa amakholomu (indlela yejeli ye-microcolumn) iyindlela evame ukusetshenziswa yokuzivikela komzimba yokuhlonza iqembu legazi, lapho ama-antigen amangqamuzana abomvu egazi kanye nama-antibodies ahambisanayo ehlangana endaweni yejeli ye-microcolumn. Le ndlela ijwayelekile futhi ilinganiswa, okuqinisekisa ukunemba kwemiphumela.
Izinyathelo ezilandelayo zihilelekile kule nqubo:
1. Ukuqoqwa kwamasampula egazi (qaphela: amasampula aqukethe iphrotheni ye-serum ekhuphuke ngokungavamile kufanele agezwe ngokwanele ngaphambi kokusetshenziswa).
2. Ukucutshungulwa kwesampula yegazi:
(i) Faka i-Centrifuge isampula yegazi lonke elingajiyile ku-900 ~ 1000g amandla e-centrifugal imizuzu emi-5, ungqimba olungezansi amaseli abomvu egazi ahlanganisiwe anokuhlushwa okungaba ngu-80%. Munca ngokucophelela i-plasma ephezulu kwenye ithubhu yokuhlola, engasetshenziswa ngqo ekuhlolweni.
(ii) Nciphisa amangqamuzana abomvu egazi agcwele ukuze ahlolwe: Thatha amangqamuzana abomvu egazi agcwele angu-8-10μl bese ufaka i-diluent yamaseli abomvu egazi engu-1ml. Ukubukeka kufanele kube obomvu okhanyayo ofanayo ongenama-flocs noma ama-clots egazi. (iii) Nciphisa amangqamuzana abomvu egazi: Thatha amangqamuzana abomvu egazi agcwele angu-8-10μl bese ufaka i-diluent yamaseli abomvu egazi engu-1ml. Ukubukeka kufanele kube obomvu okhanyayo ofanayo ongenama-flocs noma ama-clots egazi.
3. Ukusebenza kwekhadi lohlobo lwegazi:
1) Maka ikhadi le-reagent lejeli eliphilayo elilungisiwe.
2) Faka i-suspension yamaseli abomvu egazi elungisiwe kumapayipi okuqala kuya kwesine ngokulandelana, bese ufaka amaseli abomvu egazi ahlanjululwe aphendukezelwe kumapayipi esihlanu kuya kwesithupha.
3) Faka i-centrifuge ngokushesha imizuzu emi-5 (900rpm imizuzu emi-2, 1500rpm imizuzu emi-3) ku-centrifuge yekhadi lohlobo lwegazi, bese ukhipha umphumela wokwahlulela kwamehlo angenalutho.
Design
● Ukulawulwa kwe-Microprocessor nge-Brushless Motor. Ukulawulwa kwesivinini okunembile.
● Ukusebenza okulula. Isikrini sedijithali esinemibala sibonisa wonke amapharamitha asebenzayo. Isivalo esizenzakalelayo - vula i-alamu uma ithuluzi livaliwe.
● Umklamo wohlelo lobuchwepheshe. Asikho isidingo sokuhlela ngesandla. Vele uyisebenzise.

Kuyasebenziseka
● Ukuvala isivalo okuzenzakalelayo nokubamba ngesikhathi sokugijima kwe-rotor.
● Isistimu yokuzihlola ene-chamber-coating ephezulu kanye nokuvikela.
● "Thulisa" ubuchwepheshe obunelungelo lobunikazi, ukusebenza kwesivinini esiphezulu kungaphansi kwama-decibel angu-50.
● Ukuguqulwa kwe-rpm/rcf okuzenzakalelayo.

Ukuphepha
● Ikhiqizwe ngokwemithetho yezokuphepha yamazwe ngamazwe (isb. I-IEC 61010).
● Ukuphepha Ukuxhumana kwesivalo sikagesi, isicabha asikwazi ukuvuleka uma i-rotor isebenza futhi umshini ngeke usebenze lapho isivalo sivuleka futhi kuvela ikhodi yephutha.
● Ukukhululwa kwesivalo sesivalo esiphuthumayo lapho amandla ephela (iwusizo kakhulu ekuphazamisekeni kwamandla okungalindelekile).
● Izivikelo zokuphepha zenzelwe isivinini esingaphezulu ukuqinisekisa ukuphepha komshini womuntu.

| Ibanga lesivinini(rpm) | 0-3500rpm eshintshwayo | Umsindo (dBA) | ≦50 dB(A) |
| Umthamo omkhulu(ml) | Amakhadi angu-24 | Isilinganiso (mm) | 430*320*250mm (amakhadi angu-12) 440*400*230mm (amakhadi angu-24) |
| Ububanzi be-RCF (xg) | 0-1554xg elungisekayo | isisindo Net | 13 KG (namakhadi ayi-12) 22KG (namakhadi angu-24) |
| Amandla kagesi | I-AC220V, 50HZ, 5A, 60W | ||
| Cha | Into | Umthamo | Ijubane lokujikeleza | I-Max.RCF | Isikhathi | Note |
NO.1
| Iqembu lohlelo lwe-pre-centrifuge | Amakhadi angama-12 | 3500r / iminithi | 1232xg | 1 iminithi | Iqembu lohlelo lingabekwa lamakhadi ezinhlobo ezahlukene zegazi. |
NO.2
| Iqembu lohlelo lokuhlola | Amakhadi angama-12 | 900r / iminithi | 81xg | Imizuzu engu-2 | |
| 1500r / iminithi | 226xg | Imizuzu engu-3 | ||||
NO.1
| Iqembu lohlelo lwe-pre-centrifuge | Amakhadi angama-24 | 3500r / iminithi | 1554xg | 1 iminithi | |
NO.2
| Iqembu lohlelo lokuhlola | Amakhadi angama-24 | 800r / iminithi | 81xg | Imizuzu engu-2 | |
| 1335r / iminithi | 226xg | Imizuzu engu-3 | ||||
![]() | ||||||
1. Umkhiqizi we-centrifuge ochwepheshe, intengo yokuncintisana.
I-2.ISO9001, ISO13485, CE, Isitifiketi se-SFDA, yonke imishini ihlolwa ngekhwalithi eqinile kanye nokupakishwa okuhle ngaphambi kokuthutha.
3.Ukwesekwa kobuchwepheshe besikhathi eside kanye nokusiza amakhasimende okuphrofeshinali kuzo zonke izigaba zokudayiswa komkhiqizo, ukulethwa nokusebenza.Ithimba lethu lesevisi eliqeqeshwe kakhulu nelinolwazi oluningi likunikeza izinga eliyingqayizivele lokusekelwa ekuthengeni kwakho ukuphila kwakho konke.
4.Singakwazi futhi ukunikeza izixazululo ezenziwe ngokwezifiso zezidingo ezikhethekile zamakhasimende.
5.Inikwe amandla ngeqembu elisebenza kahle lonjiniyela elisekelwa isipiliyoni seminyaka emikhakheni eyahlukene, inkampani iqinisekisa ukuthi umkhiqizo ngamunye oshiya iyunithi yokukhiqiza usezingeni eliphezulu ngazo zonke izici.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ