Izincomo Zokusetshenziswa Kwezindawo Zaselabhorethri Ezindaweni Ezinkulu
Ama-centrifuge aselabhorethri amathuluzi avame ukusetshenziswa asebenzisa amandla amaphakathi akhiqizwa amakhanda ajikelezayo ukuze ahlukanise izinto zokuminyana okuhlukile noma osayizi bezinhlayiyana ekumisweni noma emimulsion.
I-Laboratory Centrifuges zisetshenziswa kabanzi kwezokwelapha, izimonyo, izibhedlela zamazinyo, amakhemikhali, ukudla, imithi, ukuvikelwa kwemvelo, izimayini, ukufundisa & ucwaningo kanye neminye imikhakha.
Amapharamitha we-centrifuge (afana nesivinini sokujikeleza, umthamo weshubhu elilodwa, isikhathi, izinga lokushisa nezinye izinkomba) ezidingekayo ukuze kucutshungulwe amasampula emikhakheni ehlukene ahlukile, kubalulekile ukukhetha okokusebenza kwe-centrifuge okufanelekile ngokusekelwe ezimfuneko ezithile zokuhlola.

Inkambu yezokwelapha:
Amasampula avame uku-centrifuged emkhakheni wezokwelapha ahlanganisa: amasampula egazi, amasampula omchamo, amasampula endle, njalonjalo;
① I-Centrifugation yamasampula egazi: ngokuvamile idinga isivinini sokujikeleza esingaba ngu-3000 rpm cishe imizuzu eyi-10.
② Isampula yokulinganisa umchamo: Imvamisa idinga isivinini esingaba ngu-1800 rpm, isikhathi esingaba yimizuzu emi-5.
③ Ukufakwa phakathi kwamasampula endle: Ngokuvamile kudinga isivinini esingaba ngu-1,000 rpm cishe imizuzu eyi-10.

Izimonyo kanye Nemitholampilo Yamazinyo:
I-Cosmetology kanye nezibhedlela zamazinyo ngokuvamile zidinga ukuhlukanisa i-PRP, i-PRF ne-CGF;
① I-PRP (I-Platelet-Rich Plasma): Ivamise ukwenziwa ngesivinini esisuka ku-300 ukuya ku-3500 rpm cishe imizuzu engu-5, ivamise ukuphindwa izikhathi eziningi.
② PRF (Platelet-Rich Fibrin): Ivamise ukwenziwa ngesivinini esisukela ku-2000 kuye ku-3000 rpm cishe imizuzu eyi-7,i-centrifugation eyodwa;.
③ I-CGF (Izici Zokukhula Ezigxilisiwe): Ifaka phakathi izinyathelo eziningi eziguquguqukayo zejubane lokuhlanganisa.

Ucwaningo lwe-Biochemical:
①Ngemvula nokuqoqwa kwamaseli, ama-nuclei, ulwelwesi lwamaseli, njll.: Ngokuvamile kwenziwa kusetshenziswa ama-rotor centrifuges avundlile anesivinini esiphansi.
② Ukulungiselela nokuqoqwa kwama-microorganisms, izingcezu zamaseli, ama-organelles amakhulu, njll.: Ngokuvamile kwenziwa kusetshenziswa ama-centrifuges anesivinini esikhulu.
③ Ukuze kuhlukaniswe, ukuhlanzwa, ukuhlonza kanye nokuhlaziywa kwe-mitochondria, ama-microsomes, ama-chromosome, ama-lysosomes, ama-plasmid, ama-molecule amakhulu e-nucleic acid, ama-macromolecules amaprotheni, njll.: Idinga i-ultracentrifugation usebenzisa i-ultracentrifuges.
Imboni Yokudla:
① Izinsalela zokuhlola ukucutshungulwa kwe-centrifugal: ngokuvamile kudinga isivinini esingaba ngu-4000 rpm, isikhathi se-centrifugation cishe imizuzu emi-5;
② Ukukhipha isitashi esixukwini sesitashi, ukhilimu noma ukwahlukaniswa kobisi oluyisikhilimu, ukucwebezeliswa kotshwala kamama, kanye nokuthuthukisa ubumsulwa: Kusebenzisa ama-centrifuge anejubane eliphansi noma izinga lokushisa eliphansi.
③ Ukuhlukaniswa kwezinhlamvu kusuka obisini: Ngokuvamile kwenziwa kusetshenziswa ama-centrifuges anesivinini esikhulu.
Khumbula, imodeli efanele ye-centrifuge kufanele ikhethwe ngokusekelwe kuhlelo lokusebenza oluthile, uhlobo lwesampula, nezimfuneko zokuhlola kunkambu ngayinye.